Crossref Cited-by Linking

  • Zahra Heidari, Mahboubeh Masrournia: A Novel Modified Carbon Paste Electrode for the Determination of Chromium(III) in Water. J Anal Chem 2018, 73, 824. <https://doi.org/10.1134/S1061934818080105>
  • Toghill Kathryn E., Xiao Lei, Wildgoose Gregory G., Compton Richard G.: Electroanalytical Determination of Cadmium(II) and Lead(II) Using an Antimony Nanoparticle Modified Boron‐Doped Diamond Electrode. Electroanalysis 2009, 21, 1113. <https://doi.org/10.1002/elan.200904547>
  • Kalcher Kurt, Svancara Ivan, Buzuk Marijo, Vytras Karel, Walcarius Alain: Electrochemical sensors and biosensors based on heterogeneous carbon materials. Monatsh Chem 2009, 140, 861. <https://doi.org/10.1007/s00706-009-0131-9>
  • Tarley César Ricardo Teixeira, Santos Vivian Silva, Baêta Bruno Eduardo Lobo, Pereira Arnaldo César, Kubota Lauro Tatsuo: Simultaneous determination of zinc, cadmium and lead in environmental water samples by potentiometric stripping analysis (PSA) using multiwalled carbon nanotube electrode. Journal of Hazardous Materials 2009, 169, 256. <https://doi.org/10.1016/j.jhazmat.2009.03.077>
  • Vytřas Karel, Svancara Ivan, Metelka Radovan: Carbon paste electrodes in electroanalytical chemistry. J Serb Chem Soc 2009, 74, 1021. <https://doi.org/10.2298/JSC0910021V>
  • Švancara Ivan, Walcarius Alain, Kalcher Kurt, Vytřas Karel: Carbon paste electrodes in the new millennium. Open Chemistry 2009, 7. <https://doi.org/10.2478/s11532-009-0097-9>
  • Sherigara B.S., Shivaraj Y., Mascarenhas Ronald J., Satpati A.K.: Simultaneous determination of lead, copper and cadmium onto mercury film supported on wax impregnated carbon paste electrode. Electrochimica Acta 2007, 52, 3137. <https://doi.org/10.1016/j.electacta.2006.09.055>
  • Trace Mercury Determination by Differential Pulse Anodic Stripping Voltammetry Using Polythiophene-Quinoline/Glassy Carbon Modified Electrode. Bulletin of the Korean Chemical Society 2003, 24, 27. <https://doi.org/10.5012/bkcs.2003.24.1.027>
  • Švancara Ivan, Ogorevc Božidar, Hočevar Samo B., Vytřas Karel: Perspectives of Carbon Paste Electrodes in Stripping Potentiometry. ANAL. SCI. 2002, 18, 301. <https://doi.org/10.2116/analsci.18.301>