Collect. Czech. Chem. Commun. 1989, 54, 3043-3060
https://doi.org/10.1135/cccc19893043

Segmented electrodiffusion probes: Simultaneous measurement of shear rate and normal flow component

Ondřej Wein and Václav Sobolík

Institute of Chemical Process Fundamentals, Czechoslovak Academy of Sciences, 165 02 Prague 6-Suchdol

Abstract

The existing theory of direction-sensitive electrodiffusion probes for the wall shear rate measurement is extended by including normal flow effects.